[Shandong TV House inspection group: Greentown Mingyue Fenghe Community] The double -sided glue of the new house floor is not removed?

Author:Qilu.com Time:2022.08.09

Qilu.com · Lightning News August 9th Mr. Zhao from Jinan reported to reporters that he spent more than 2 million yuan from Greentown Yuefenghe District to buy a new 143 square meter. If you have quality problems, you are invited to check the Shandong Television House inspection group.

Double -sided glue of Xinfang Floor Floor Building?

The Shandong TV House inspection group came to the house of Mr. Zhao, which is located in the Mingyue Fenghe Community, Greentown, Jinan. So, is there a quality problem in this new house of Mr. Zhao? Today, the home inspection group invited a professional home inspector Wang Qinghua to conduct an overall inspection of the house from the living room.

First of all, we can see that the on -site home inspector eliminates the putty layer of the roof panel and leaked the white double -sided glue.

The home inspector Wang Qinghua said that this is concrete, the outside is double -sided glue, and there is a layer of sand ash outside. When the concrete is poured, the template on the surface of the surface is to prevent leakage. If it is poured into the inside of the concrete, it will affect the thickness of the surface of the surface of the surface of the surface. This should not be. After the construction enterprise was built, it was not excluded that the double -sided glue would cause the bellies of the floor to crack and fall off.

The height of the living room floor is 3 times more than the regulations

The home inspector also found that there was a problem with the flatness of the roof of the living room. The maximum measurement of the tape ruler is 15 mm, the flatness has exceeded 15 mm, and the standard of delivery of the rough house is less than 4 mm. After the measurement of the ruler and the ruler, it exceeded three times the specified value.

Judging from the inspection of the living room, the top board not only eliminated double -sided glue, but also there are also unevenness of flatness. The housekeeper suggested that the owner, Mr. Zhao, eliminated the putty layer of the living room to see if there are similar situations. occur. After checking the living room, the home inspectionist found a problem in the second bedroom.

The bedroom roof has low concrete strength strength

When I came to the second bedroom, when the home inspection cleaned to touch the area, it was found that it was not concrete at all, and the cement sands were very obvious.

In order to confirm his own statement, the inspector took out the concrete rebate device for testing. After the rebound, the values ​​that were not repaired on both sides were 43 and 45, respectively. The minimum value of the middle repair is the lowest, reaching 29.

Regarding the problem of low strength of the floor building, the housekeeper suggested to find a third -party appraisal unit to conduct professional appraisal of the thickness of the steel protective layer and whether it affects the safety of the structure after drooping. Then, according to the appraisal report, the reinforcement plan is formulated, not just the surface of the surface of the surface of the surface.

For the problems of building a building, how do you deal with Jinan Quanyi Real Estate Co., Ltd., a construction unit in the community? The reporter contacted the property housekeeper responsible for Mr. Zhao.

When the reporter proposed to contact the developer and the construction party to check with Mr. Zhao's house, the staff of the property housekeeper of the Jinan Greentown Yuefenghe District property house replied that the development enterprise and the construction unit would go to the scene to deal with it at 2 pm.

Hidden dangers of waterproof storage on the wall of the new house toilet

At 1:30 in the afternoon, the reporter came to Mr. Zhao's house again. While waiting, the housekeeper found a hidden danger in waterproofing the wall of the bathroom.

The waterproof of the bathroom is made on the surface and inner side. There is no effective link. The middle is mixed with plastering layers. Once the water seeps, it will follow the waterproof inner side to the opposite side of the wall, causing the yin water, humidity, and mold on the opposite side. The surface of the wall is brushed waterproof, and tiles will not be firm in the later stage. On the north side of the bathroom, the reporter found that the waterproof layer had cracking.

Regarding the waterproof problem of the bathroom, the housekeeper suggested that the waterproof area of ​​the surface is shovel and re -water the waterproof. Only by linking the internal and ground waterproof layers of the protective layer and the ground with 30 cm of the ground can the strong and hard drums of the tile stickers be guaranteed, and the water penetrates the opposite side.

Developer: Refuse to respond to no interview

At 2:10 in the afternoon, the staff of the development company came to Mr. Zhao's house. When the reporter stepped forward to consult, it was rejected by the staff. The staff member said that he could not accept the media interview without being licensed by the company.

Because the staff refused to respond, Mr. Zhao's house problem was not resolved and dealt with.The reporter hopes that as the head of the community's development company, Jinan Quanyi Real Estate Co., Ltd., after watching the show, personnel will arrange personnel to handle and resolve them as soon as possible.The reporter will continue to pay attention to this matter.

- END -

Exposure!These units have hidden fire safety hazards

Liangdang County Binhe Road Linshui No. 1 KTV CorridorFire safety hazards: fire ex...

After paying 80,000 furniture, the delivery time has not been placed!Merchant reply is speechless

Recently, Ms. Liu from Guiyang, Guizhou is renovating a new homeA shop in Hongxing...