An important regulations on Anhui are related to your house!

Author:Anhui released Time:2022.09.07

House cracks, indoor leaks, exterior walls fall off

Native

Beside the citizen

There are some common housing quality common problems

How to effectively prevent governance?

Published by the Housing and Construction Department of Anhui Province

"Technical Regulations for Prevention and Control of House Engineering Quality"

Recently, it has begun implementation

It will promote the overall level of quality of residential engineering

The new local standards in the province's "Technical Regulations on the Prevention and Control of the Quality of Housing Engineering" have been released and implemented, and the attention of social complaints will be further guaranteed to ensure the function of residential use functions and sense of view.

The new regulations propose that the living room, bedroom, study room and other main functional rooms of each household should be checked at the living room, bedroom, and study room. The judgment of space size deviations is based on each household, and the inspection points indoors are complied with the provisions of this regulation, and the maximum deviation does not exceed 1.5 times the allowable deviation, which can be judged as qualified. When the size of the space does not meet the requirements of this regulation, the reasons should be analyzed in combination with the test results such as the ground and the wall flat, and reasonable rectification measures should be taken.

The flexibility of the doors and fan switches and strict shutdown are a hot spot in the quality complaint of new houses. In many high -rise houses, the bedroom is equipped with convex windows, which can enjoy more sufficient indoor light and can also be used as an observation deck. However, the protection settings of the convex windows are not at the time, and it is easy to cause hidden safety hazards. Therefore, the new regulations make special regulations on the protection of convex windows. When the window sill is lower than or equal to 0.45m, the protection height should not be less than 0.90m from the window sill; when the net level of the bottom of the window and window hole can be turned on, the net should have protective measures at the window hole. It should not be less than 0.90m from the window sill. In addition, all doors and windows must be switched and offwriters to ensure no use failure.

The quality of residential air is directly related to human health. Considering that the maintenance and volatilization period of coatings is generally one week, the new regulations require the inspection of the indoor environment quality after 7 days after the project is completed. With the gradual popularization of firing houses, testing the indoor environmental pollution concentration of full renovation residential houses should be tested.

- END -

Xinhua Full Media+| my country ’s trillion yuan electronic information industry challenge is welcomed by the new machine

Faced with the complex domestic and foreign situations and many risk challenges in...

Taiyuan: The decoration community \"stopped\" in time during the decoration community du

On June 6, the parents of the candidates complained to the Normal Street Communi...